Flexbot design

From Rsewiki
Revision as of 13:55, 22 April 2018 by Jca (Talk | contribs)

Jump to: navigation, search

Back to Flexbot main page

Contents

Design overview hardware

Each "leg" of the flexbot consists of 4 actuators.

  • An angled DC motor to control the wheel.
  • Two linear actuators to control the motion of the robot's body.
  • A linear actuator to adjust heading angle on the wheel.

Each of the legs are interfaced and controlled by μ-processor boards (Teensy 3.5). Each leg is split up in two parts which are presented as the ankle configuration and the knee configuration. The hardware design for robot's body is presented here.

A complete 3D model of the robot is available using the online CAD software Onshape.com - JCA should be contacted for sharing and editing the model.

Each leg part is connected with a two parallel stretches (mostly carbon tubes), each 4 carbon tubes, from foot to knee and from knee to hip (see also Flexbot 3D print).

Tube geometry.png

Figure 1. Basic geometry for both upper and lower leg.

Ankle hardware design

The ankle configuration currently includes:

Knee hardware design

The knee configuration currently includes:

  • A linear actuator to control the height (tilt) of the configuration - model DLA-12-10-A-200-IE?-IP66 (2 each leg)
  • Cytron 10A DC Motor Driver - model RB-Cyt-132
  • MPU to obtain tilt - model MPU-9250/6500 - in total 5 each leg.
  • Teensy 3.5 μ-processor board
  • Pololu 24V to 5V voltage regulator - model D24V22F5
  • Pololu 24V to 12V voltage regulator - model D24V??F12 - for steering actuator

Open items (to-do list)

This list includes items that needs to be done, but have not been finished yet. This serves as reference for where to start when catching up on the project. This list should be updated as items are finished and finished items should be moved to the list which represents the current configuration of the knee. The responsibility of updating the schematic and git repository falls to the person responsible for carrying out the open item. This way the documentation both here and on git reflects the current state of the ankle configuration.

  • The encoder counts for the DC motor at the ankle is still giving issues after ferrit cores.

Body hardware design

The design of the body hardware has not been started yet. A few ideas have been discussed bot nothing final has been decided upon. The body hardware design will first be relevant in mid/late autumn. A few discussed ideas of what the body hardware design should include are listed below:

Personal tools
Namespaces

Variants
Actions
Navigation
Toolbox