This is some suggestions for changed settings for Robobot.
+
Moved to [[regbot settings]]
 
+
== Robot configuration==
+
 
+
Metric setup
+
 
+
== Control issues ==
+
 
+
Some examples of control settings.
+
 
+
===Edge control===
+
 
+
For higher speed in the range 0.7-0.9 m/s the following control settings could be used.
+
 
+
[[File:line_edge_control.png]]
+
 
+
The control uses a Lag-controller to decrease the static gain by a factor 5 (a pole with a time constant of 1 sec and a zero with a time constant of 0.2 seconds). This means that the high frequency gain is Kp*0.2 = 0.06.
+
 
+
The gain is further scaled by the speed (from firmware version 604), so that the gain is reduced to half at 0.5m/s, but the filter times are maintained. This is probably a bad solution, as the response probably is more distance driven than time driven.
+
 
+
 
+
A test script to could be:
+
 
+
thread=1
+
    vel=0.01, acc=5.0, log=20.0: time=0.2
+
    vel=0.8, edger=0.7, white=1: dist=3.0, xw=20, log=0
+
    label=3, event=3: xw<15
+
    edger=-0.7, white=1: dist=1.5, xw=20, log=0
+
    label=4, event=3: xw<15
+
    edger=0.7, white=1: dist=1.5, xw=20, log=0
+
    goto=3: count=1
+
    vel=0.0: time=0.5
+
 
+
The mission follows right side of line,
+
* first in a left curve (1mØ) then
+
* a crossing line,
+
* wait for line to disappear, 
+
* a right curve (1mØ),
+
* a crossing white line
+
* ...
+
 
+
The difference between a left and a right curve is the "edger=0.7" and "edger=-0.7", this makes the robot follow the offset by 0.7cm towards the center of the curve (more left in a left curve).
+

Latest revision as of 14:04, 17 March 2017