Regbot maintenance

From Rsewiki
Revision as of 12:49, 31 December 2018 by Jca (Talk | contribs)

Jump to: navigation, search

Back to Regbot main page.

Battery maintenance

The battery is a 3-cell Lithium polymer type with a capacity of 1Ah and a nominal voltage of 11.1 V.

Lithium batteries has a longer life when stored at the nominal voltage (50% charged), so we try to keep this when robots are not used.

Lithium batteries will be destroyed or damaged if discharged below 3.2V per cell (9.8V).

The build-in charger is of different types (internally), and some of then discharge the battery, when not charging. They discharge with between 0.5 to 5 mA. i.e a fully charged battery is drained after between 200 and 2000 hours.

After charging a battery with a leaky charger, remove the charge cable as shown in figure below.

Charger-plugged-and-unplugged.png

Figure 1. Some of the chargers destroy the battery when unused for a period of time, so on most robots the charge cable is disconnected. Reconnect to charger when needed.

Personal tools
Namespaces

Variants
Actions
Navigation
Toolbox